5999-01-053-0668 CONTACT,ELECTRICAL Index 1680-01-053-0671 HOUSING,BEARING

National Stock Number:
5970-01-053-0669

Federal Supply Class:
5970

National Item Identification Number:
010530669

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
202-25212-780378TRIUMPH AEROSTRUCTURES, LLC
382A034-406090TE CONNECTIVITY CORPORATION
382A034-4-006090TE CONNECTIVITY CORPORATION
493H145-6209993M CO ADMININISTRATIVE ELECTRONIC & COMMUNICATIONS
493H145-675037MINNESOTA MINING AND MFG CO 3M COMPANY
493H145-67V059MINNESOTA MINING AND MFG CO


Techincal Specification:
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG22.5 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES2.580 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH3.220 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
MAIN BODY WALL THICKNESS0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.710 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.520 INCHES MINIMUM AS SUPPLIED
MATERIALPLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED
MINIMUM TENSILE STRENGTH1200 POUNDS PER SQUARE INCH
SPECIAL FEATURESADHESIVE COATING
SECOND BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-Y
TEMP RATING-55.0 CELSIUS AND 135.0 CELSIUS