5970-01-134-1315 INSULATION SLEEVING,ELECTRICAL Index 4720-01-134-1317 HOSE,AIR DUCT

National Stock Number:
5970-01-134-1316

Federal Supply Class:
5970

National Item Identification Number:
011341316

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
382A023-3-06/4206090TE CONNECTIVITY CORPORATION
GS830AE6-3-4226512NORTHROP GRUMMAN SYSTEMS CORPORATION


Techincal Specification:
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG22.5 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES1.810 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH1.550 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.750 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYSEMIRIGID
MAIN BODY WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
MATERIAL DOCUMENT AND CLASSIFICATIONRT-301, RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED
MATERIALPLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
SPECIAL FEATURESADHESIVE COATING INSIDE
SECOND BRANCH INSIDE DIAMETER0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.750 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-Y
TEMP RATING-55.0 CELSIUS AND 135.0 CELSIUS