6515-01-149-9071 CATHETER,CARDIOVASCULAR Index 4730-01-149-9073 FLANGE,PIPE

National Stock Number:
5970-01-149-9072

Federal Supply Class:
5970

National Item Identification Number:
011499072

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
403A134-3/4206090TE CONNECTIVITY CORPORATION
403A134-41/4206090TE CONNECTIVITY CORPORATION


Techincal Specification:
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.250 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.870 INCHES MINIMUM AS SUPPLIED
FLEXIBILITYFLEXIBLE
MAIN BODY OVERALL LENGTH3.750 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.110 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.900 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.750 INCHES MINIMUM AS SUPPLIED
MATERIAL DOCUMENT AND CLASSIFICATIONRT-1304,RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE
MATERIALPLASTIC POLYOLEFIN
MINIMUM TENSILE STRENGTH1200 POUNDS PER SQUARE INCH
SECOND BRANCH INSIDE DIAMETER0.250 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.870 INCHES MINIMUM AS SUPPLIED
SPECIAL FEATURESINSIDE S1017 ADHESIVE COATED
TEMP RATING-55.0 CELSIUS