5970-01-191-4905 INSULATION SLEEVING,ELECTRICAL Index 1310-01-191-4907 PROJECTILE METAL PARTS ASSEMBLY

National Stock Number:
5970-01-191-4906

Federal Supply Class:
5970

National Item Identification Number:
011914906

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
622A014-306090TE CONNECTIVITY CORPORATION
C5075979-2957958SIGNALS WARFARE PROJECT MANAGER


Techincal Specification:
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH1.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.220 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYSEMIRIGID
FOURTH BRANCH INSIDE DIAMETER0.220 INCHES MINIMUM AS SUPPLIED
FOURTH BRANCH INSIDE DIAMETER0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FOURTH BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.600 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.000 INCHES MINIMUM AS SUPPLIED
MAIN BODY OVERALL LENGTH4.620 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.080 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL DOCUMENT AND CLASSIFICATIONRT-301, RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED
MATERIALPLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
SECOND BRANCH INSIDE DIAMETER0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.220 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
TEMP RATING-55.0 CELSIUS
THIRD BRANCH INSIDE DIAMETER0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.220 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY


Click here to Register for Free 30-day Trial