A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
222D221-406090TE CONNECTIVITY CORPORATION
222D221-4-006090TE CONNECTIVITY CORPORATION
912132-13B150RAYTHEON COMPANY
912132-149956RAYTHEON COMPANY
333D332-67V059MINNESOTA MINING AND MFG CO


Techincal Specification:
DISTANCE FROM TOP OF SHOULDER TO SMALL END OF MAIN BODY3.900 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
END LARGEST DIAMETER0.600 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FLEXIBILITYFLEXIBLE
HEIGHT0.780 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
LARGE END WALL THICKNESS OF MAIN BODY0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
LIP HEIGHT0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
LIP WIDTH0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY LARGE END INSIDE DIAMETER1.010 INCHES MINIMUM AS SUPPLIED
MAIN BODY OVERALL LENGTH4.880 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY SMALL END INSIDE DIAMETER0.290 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY SMALL END INSIDE DIAMETER1.010 INCHES MINIMUM AS SUPPLIED
MAIN BODY LARGE END INSIDE DIAMETER0.590 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MATERIAL DOCUMENT AND CLASSIFICATIONRT-1304,RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED
MATERIALPLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED
MINIMUM TENSILE STRENGTH1200 POUNDS PER SQUARE INCH
SMALL END WALL THICKNESS OF MAIN BODY0.045 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORBOOT-90 DEGREES
TEMP RATING-55.0 CELSIUS