5970-01-282-5570 INSULATION SLEEVING,ELECTRICAL Index 4920-01-282-5572 MEASURING SECTION

National Stock Number:
5970-01-282-5571

Federal Supply Class:
5970

National Item Identification Number:
012825571

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
228A042-25-0006090TE CONNECTIVITY CORPORATION


Techincal Specification:
DISTANCE FROM INTERSECTING CENTERLINES TO EDGE OF SMALL END1.560 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM TOP OF SHOULDER TO SMALL END OF MAIN BODY0.370 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN LARGE END AND SMALL END CENTERLINES IN DEG45.0 NOMINAL AS SUPPLIED
ANGLE BETWEEN LARGE END AND SMALL END CENTERLINES IN DEG90.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS300.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM CENTERLINE OF SMALL END TO EDGE OF LARGE END0.660 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT
FLEXIBILITYSEMIRIGID
HEIGHT1.300 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
LARGE END WALL THICKNESS OF MAIN BODY0.110 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY LARGE END INSIDE DIAMETER0.700 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY LARGE END INSIDE DIAMETER0.940 INCHES MINIMUM AS SUPPLIED
MAIN BODY SMALL END INSIDE DIAMETER0.220 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY SMALL END INSIDE DIAMETER0.460 INCHES MINIMUM AS SUPPLIED
MATERIAL DOCUMENT AND CLASSIFICATIONRT-1325,RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED
MATERIALRUBBER LOCATION NOT OTHERWISE SPECIFIED
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
SMALL END WALL THICKNESS OF MAIN BODY0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
SPECIAL FEATURESINCLUDES MOLDING PORTS
STYLE DESIGNATORBOOT-90 DEGREES


Click here to Register for Free 30-day Trial