9390-01-282-9949 NONMETALLIC CHANNEL Index 3611-01-282-9951 TYPE SET,WIRE MARKING

National Stock Number:
5970-01-282-9950

Federal Supply Class:
5970

National Item Identification Number:
012829950

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
11447850-218876U S ARMY AVIATION AND MISSILE COMMAND
310-1-JK0720HELLERMANNTYTON LTD
462A034-406090TE CONNECTIVITY CORPORATION
573H145-6763813M COMPANY
573H145-67V059MINNESOTA MINING AND MFG CO
310-1-JK1793HELLERMANNTYTON LIMITED


Techincal Specification:
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH2.900 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS225.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES2.420 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
MAIN BODY INSIDE DIAMETER0.740 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.520 INCHES MINIMUM AS SUPPLIED
MAIN BODY OVERALL LENGTH5.320 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MATERIAL DOCUMENT AND CLASSIFICATIONRT-1304,RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED
MATERIALPLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED
MINIMUM TENSILE STRENGTH1200 POUNDS PER SQUARE INCH
SECOND BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-1 TO 3 CABLES
TEMP RATING-55.0 CELSIUS
THIRD BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY