6150-01-291-9362 CABLE ASSEMBLY,SPECIAL PURPOSE,E Index 5977-01-291-9364 HOLDER,ELECTRICAL CONTACT BRUSH

National Stock Number:
5970-01-291-9363

Federal Supply Class:
5970

National Item Identification Number:
012919363

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
462A046-406090TE CONNECTIVITY CORPORATION
573H157-6209993M CO ADMININISTRATIVE ELECTRONIC & COMMUNICATIONS
573H157-675037MINNESOTA MINING AND MFG CO 3M COMPANY
573H157-67V059MINNESOTA MINING AND MFG CO


Techincal Specification:
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH4.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS225.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES3.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
MAIN BODY OVERALL LENGTH7.560 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER2.190 INCHES MINIMUM AS SUPPLIED
MATERIALPLASTIC POLYOLEFIN
MINIMUM TENSILE STRENGTH1200 POUNDS PER SQUARE INCH
SECOND BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-1 TO 3 CABLES
TEMP RATING-55.0 CELSIUS
THIRD BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY


Click here to Register for Free 30-day Trial