5970-01-554-8520 INSULATION SLEEVING,ELECTRICAL Index 5970-99-000-3083 INSULATOR,STANDOFF

National Stock Number:
5970-12-308-5088

Federal Supply Class:
5970

National Item Identification Number:
123085088

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
411-1-GW24D8527HELLERMANN TYTON GMBH
411-1-GW24K1793HELLERMANNTYTON LIMITED
562A022-25/225-0 0198GTE CONNECTIVITY TRUTNOV S.R.O.
562A022-25/225-00382GTYCO ELECTRONICS CZECH S.R.O.
562A022-25/225-0K1010TYCO ELECTRONICS UK LTD
562A022-25/225K1010TYCO ELECTRONICS UK LTD
VG95343T19E002AD9477BUNDESAMT FUER AUSRUESTUNG,
562A022-25/225-0SU473TYCO ELECTRONICS TECNOLOGIAS, S.A. DE C.V.


Techincal Specification:
III SUPPLEMENTARY FEATURESMASSE DES UNVERPACKTEN ARTIKELS:8,5 GRAMM
RELIABILITY INDICATORESTABLISHED
SECOND BRANCH INSIDE DIAMETER5,5 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES36,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH32,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH36,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
COLORBLACK
ENVIRONMENTAL PROTECTIONMILDEW RESISTANT
FIRST BRANCH INSIDE DIAMETER5,5 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER8,5 MILLIMETERS MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS1,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
FOURTH BRANCH INSIDE DIAMETER5,5 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
FOURTH BRANCH INSIDE DIAMETER8,5 MILLIMETERS MINIMUM AS SUPPLIED
FOURTH BRANCH WALL THICKNESS1,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH71,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER10,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER18,0 MILLIMETERS MINIMUM AS SUPPLIED
MAIN BODY WALL THICKNESS2,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER8,5 MILLIMETERS MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS1,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
SPECIAL FEATURESMIT INNENBESCHICHTUNG
STYLE DESIGNATORTRANSITION-1 TO 4 CABLES
TEMP RATING150,0 DEG CELSIUS
TEST DATA DOCUMENTD9477-VG95343-2/ SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). AND D9477-VG95343-19TYP:E SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
THIRD BRANCH INSIDE DIAMETER5,5 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER8,5 MILLIMETERS MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS1,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY