5985-00-070-8132 WAVEGUIDE ASSEMBLY Index 1285-00-070-8136 WINDOW

National Stock Number:
5985-00-070-8133

Federal Supply Class:
5985

National Item Identification Number:
000708133

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
100272756232LOCKHEED MARTIN CORPORATION
232288010001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
23228805Z167ASTRO MICROWAVE INC


Techincal Specification:
STYLE DESIGNATORBEND TYPE
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
TUBING WALL CONSTRUCTION STYLESEAMLESS ALL TUBING SEGMENT
FLANGE QUANTITY2
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE STYLECHOKE TYPE FIRST FLANGE
COVER TYPE SECOND FLANGE
FLEXIBILITYRIGID ALL TUBING SEGMENT
MATERIALALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE
WAVEGUIDE LONGER OFFSET DISTANCE5.719 INCHES MINIMUM AND
5.781 INCHES MAXIMUM
WAVEGUIDE OFFSET DISTANCE0.500 INCHES NOMINAL
WAVEGUIDE OUTSIDE WIDTH0.996 INCHES MINIMUM AND
1.004 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH0.896 INCHES MINIMUM AND
0.904 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.396 INCHES MINIMUM AND
0.404 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.496 INCHES MINIMUM AND
0.504 INCHES MAXIMUM
BEND ANGLE IN DEG90.0 ALL BENDS H-PLANE
SURFACE TREATMENTSILVER AND
GOLD SINGLE TUBING SEGMENT INSIDE SURFACES
CHROMATE AND
CHROMATE ZINC AND
ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
FLANGE INSIDE WIDTH0.896 INCHES MINIMUM AND
0.904 INCHES MAXIMUM FIRST FLANGE
1.003 INCHES MINIMUM AND
1.006 INCHES MAXIMUM SECOND FLANGE
FLANGE INSIDE HEIGHT0.396 INCHES MINIMUM AND
0.404 INCHES MAXIMUM FIRST FLANGE
0.503 INCHES MINIMUM AND
0.506 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE WIDTH1.610 INCHES MINIMUM AND
1.640 INCHES MAXIMUM FIRST FLANGE
1.610 INCHES MINIMUM AND
1.640 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE HEIGHT1.610 INCHES MINIMUM AND
1.640 INCHES MAXIMUM FIRST FLANGE
1.610 INCHES MINIMUM AND
1.640 INCHES MAXIMUM SECOND FLANGE
FLANGE DEPTH0.423 INCHES MINIMUM AND
0.453 INCHES MAXIMUM FIRST FLANGE
0.423 INCHES MINIMUM AND
0.453 INCHES MAXIMUM SECOND FLANGE
FLANGE CONNECTING HOLE DIAMETER0.169 INCHES MINIMUM AND
0.172 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES
THREAD SERIES DESIGNATORUNC FIRST FLANGE ALL CONNECTION FACILITIES
NOMINAL THREAD SIZE0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
THREAD CLASS32 FIRST FLANGE ALL CONNECTION FACILITIES
THREAD DIRECTIONRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
MAXIMUM OPERATING PRESSURE10.0 POUNDS PER SQUARE INCH GAGE
SPECIAL FEATURESTUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED
PRECIOUS MATERIALGOLD AND
SILVER
PRECIOUS MATERIAL AND LOCATIONINTERNAL SURFACES GOLD AND
INTERNAL SURFACES SILVER
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT