5910-00-238-2594 CAPACITOR,FIXED,CER Index 5905-00-238-2599 RESISTOR,VARIABLE,NONWIRE WOUND,

National Stock Number:
5985-00-238-2595

Federal Supply Class:
5985

National Item Identification Number:
002382595

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
1067502706351MICROWAVE ENGINEERING CORPORATION
1067502718876U S ARMY AVIATION AND MISSILE COMMAND
TS64538406351MICROWAVE ENGINEERING CORPORATION


Techincal Specification:
BEND ANGLE IN DEG45.0 SECOND BEND E-PLANE
BEND ANGLE IN DEG90.0 FIRST BEND H-PLANE
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE DEPTH0.423 INCHES MINIMUM AND 0.453 INCHES MAXIMUM ALL FLANGES
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES
FLANGE CONNECTING HOLE DIAMETER0.169 INCHES MINIMUM AND 0.172 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES
FLANGE INSIDE WIDTH1.003 INCHES MINIMUM AND 1.006 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE HEIGHT0.503 INCHES MINIMUM AND 0.506 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE HEIGHT1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE WIDTH1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM ALL FLANGES
FLANGE QUANTITY2
FLANGE STYLECOVER TYPE ALL FLANGES
FLEXIBILITYFLEXIBLE SINGLE TUBING SEGMENT
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
INSERTION LOSS IN DECIBELS0.10
MATERIALCOPPER ALLOY ALL TUBING SEGMENT AND FLANGE
MATERIALRUBBER SYNTHETIC SINGLE FLANGE
MAXIMUM OPERATING PRESSURE15.0 POUNDS PER SQUARE INCH GAGE
PRECIOUS MATERIAL AND LOCATIONINTERNAL SURFACES SILVER AND EXTERNAL SURFACES RHODIUM
PRECIOUS MATERIALSILVER AND RHODIUM
STYLE DESIGNATOROFFSET BEND TYPE
VOLTAGE STANDING WAVE RATIO1.10
WAVEGUIDE CENTER TO CENTER DISTANCE1.625 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM
WAVEGUIDE LENGTH2.750 INCHES NOMINAL
WAVEGUIDE OUTSIDE HEIGHT0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM
SURFACE TREATMENTRHODIUM ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
SURFACE TREATMENTSILVER ALL TUBING SEGMENT AND FLANGE INSIDE SURFACES
TUBING WALL CONSTRUCTION STYLESEAMLESS SINGLE TUBING SEGMENT