CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE DEPTH | 0.182 INCHES MINIMUM AND 0.192 INCHES MAXIMUM FIRST FLANGE |
FLANGE DEPTH | 0.195 INCHES MINIMUM AND 0.225 INCHES MAXIMUM SECOND FLANGE |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
FLANGE CONNECTING HOLE DIAMETER | 0.116 INCHES MINIMUM AND 0.118 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
FLANGE INSIDE DIAMETER | 0.485 INCHES MINIMUM AND 0.515 INCHES MAXIMUM SECOND FLANGE |
FLANGE INSIDE HEIGHT | 0.1385 INCHES MINIMUM AND 0.1415 INCHES MAXIMUM SECOND FLANGE |
FLANGE INSIDE HEIGHT | 0.222 INCHES MINIMUM AND 0.224 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE WIDTH | 0.2785 INCHES MINIMUM AND 0.2815 INCHES MAXIMUM SECOND FLANGE |
FLANGE INSIDE WIDTH | 0.362 INCHES MINIMUM AND 0.364 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE HEIGHT | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM SECOND FLANGE |
FLANGE OUTSIDE HEIGHT | 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE WIDTH | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM SECOND FLANGE |
FLANGE OUTSIDE WIDTH | 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM FIRST FLANGE |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CHOKE TYPE SECOND FLANGE |
FLANGE STYLE | COVER TYPE FIRST FLANGE |
FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES AND RELATED EQUIP. |
INSERTION LOSS IN DECIBELS | 0.20 |
MATERIAL | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
NOMINAL THREAD SIZE | 0.112 INCHES SECOND FLANGE ALL CONNECTION FACILITIES |
PRECIOUS MATERIAL | SILVER |
PRECIOUS MATERIAL AND LOCATION | TUBING SURFACE SILVER |
STYLE DESIGNATOR | STRAIGHT TYPE |
VOLTAGE STANDING WAVE RATIO | 1.08 |
WAVEGUIDE INSIDE HEIGHT | 0.1385 INCHES MINIMUM AND 0.1415 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 0.2785 INCHES MINIMUM AND 0.2815 INCHES MAXIMUM |
WAVEGUIDE LENGTH | 0.625 INCHES NOMINAL |
WAVEGUIDE OUTSIDE HEIGHT | 0.218 INCHES MINIMUM AND 0.222 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 0.358 INCHES MINIMUM AND 0.362 INCHES MAXIMUM |
SURFACE TREATMENT | SILVER SINGLE TUBING SEGMENT OUTSIDE SURFACES |
THREAD DIRECTION | RIGHT-HAND SECOND FLANGE ALL CONNECTION FACILITIES |
THREAD CLASS | 2B SECOND FLANGE ALL CONNECTION FACILITIES |
THREAD SERIES DESIGNATOR | UNC SECOND FLANGE ALL CONNECTION FACILITIES |
THREAD QUANTITY PER INCH | 40 SECOND FLANGE ALL CONNECTION FACILITIES |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |