STYLE DESIGNATOR | BEND TYPE |
CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
FLANGE QUANTITY | 2 |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATERIAL | ALUMINUM SINGLE TUBING SEGMENT |
WAVEGUIDE LONGER OFFSET DISTANCE | 1.252 INCHES MINIMUM AND |
| 1.272 INCHES MAXIMUM |
WAVEGUIDE OFFSET DISTANCE | 0.990 INCHES MINIMUM AND |
| 1.010 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 0.996 INCHES MINIMUM AND |
| 1.004 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 0.896 INCHES MINIMUM AND |
| 0.904 INCHES MAXIMUM |
WAVEGUIDE INSIDE HEIGHT | 0.396 INCHES MINIMUM AND |
| 0.404 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE HEIGHT | 0.496 INCHES MINIMUM AND |
| 0.504 INCHES MAXIMUM |
BEND ANGLE IN DEG | 90.0 SINGLE BEND H-PLANE |
SURFACE TREATMENT | CHROMATE AND |
| PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
FLANGE INSIDE WIDTH | 0.896 INCHES MINIMUM AND |
| 0.904 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE HEIGHT | 0.396 INCHES MINIMUM AND |
| 0.404 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM AND |
| 1.640 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM AND |
| 1.640 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE DIAMETER | 1.407 INCHES MINIMUM AND |
| 1.437 INCHES MAXIMUM FIRST FLANGE |
FLANGE DEPTH | 0.423 INCHES MINIMUM AND |
| 0.453 INCHES MAXIMUM FIRST FLANGE |
THREAD SERIES DESIGNATOR | UNC FIRST FLANGE ALL CONNECTION FACILITIES |
THREAD DIRECTION | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
MAXIMUM OPERATING PRESSURE | 45.0 POUNDS PER SQUARE INCH GAGE |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |