5930-00-588-9699 SWITCH,SENSITIVE Index 1730-00-588-9702 RAM,CYLINDER,LINEAR

National Stock Number:
5985-00-588-9701

Federal Supply Class:
5985

National Item Identification Number:
005889701

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
6491166544FRONTGRADE TECHNOLOGIES INC.
6491180006LITTON SYSTEMS INC AIRTRON DIV
7410627G203538LOCKHEED MARTIN CORPORATION
CG-946/U80058JOINT ELECTRONICS TYPE DESIGNATION SYSTEM


Techincal Specification:
FLANGE DEPTH1.235 INCHES MINIMUM FIRST FLANGE AND 1.265 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE WIDTH2.834 INCHES MINIMUM FIRST FLANGE AND 2.846 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE WIDTH3.002 INCHES MINIMUM SECOND FLANGE AND 3.005 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE DIAMETER5.298 INCHES MINIMUM FIRST FLANGE AND 5.328 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE DIAMETER5.298 INCHES MINIMUM SECOND FLANGE AND 5.328 INCHES MAXIMUM SECOND FLANGE
FLANGE QUANTITY2
FLANGE STYLECHOKE TYPE FIRST FLANGE
FLANGE STYLECOVER TYPE SECOND FLANGE
FLEXIBILITYRIGID SINGLE TUBING SEGMENT
FSC APPLICATION DATAANTENNAS,WAVEGUIDES AND RELATED EQUIP.
MATERIALALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE
III STYLE DESIGNATORBEND TYPE
PROPRIETARY CHARACTERISTICSPACS
MAXIMUM OPERATING PRESSURE35.0 POUNDS PER SQUARE INCH GAGE
NOMINAL THREAD SIZE0.250 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
VOLTAGE STANDING WAVE RATIO1.05
WAVEGUIDE INSIDE HEIGHT1.334 INCHES MINIMUM AND 1.346 INCHES MAXIMUM
WAVEGUIDE LONGER OFFSET DISTANCE8.407 INCHES MINIMUM AND 8.469 INCHES MAXIMUM
WAVEGUIDE OFFSET DISTANCE1.813 INCHES MINIMUM AND 1.875 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT1.494 INCHES MINIMUM AND 1.506 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH2.994 INCHES MINIMUM AND 3.006 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH2.834 INCHES MINIMUM AND 2.846 INCHES MAXIMUM
SURFACE TREATMENTPAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
THREAD CLASS2B FIRST FLANGE ALL CONNECTION FACILITIES
THREAD DIRECTIONRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
THREAD QUANTITY PER INCH20 FIRST FLANGE ALL CONNECTION FACILITIES
THREAD SERIES DESIGNATORUNC FIRST FLANGE ALL CONNECTION FACILITIES
TUBING WALL CONSTRUCTION STYLESEAMLESS SINGLE TUBING SEGMENT
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE CONNECTING FACILITY AND QUANTITY8 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING FACILITY AND QUANTITY8 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING HOLE DIAMETER0.257 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.260 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE INSIDE HEIGHT1.334 INCHES MINIMUM FIRST FLANGE AND 1.346 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE HEIGHT1.502 INCHES MINIMUM SECOND FLANGE AND 1.505 INCHES MAXIMUM SECOND FLANGE
FLANGE DEPTH0.735 INCHES MINIMUM SECOND FLANGE AND 0.765 INCHES MAXIMUM SECOND FLANGE


Click here to Register for Free 30-day Trial