4730-00-729-5593 CLAMP,HOSE Index 5960-00-729-5600 ELECTRON TUBE

National Stock Number:
5985-00-729-5599

Federal Supply Class:
5985

National Item Identification Number:
007295599

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
918461318876U S ARMY AVIATION AND MISSILE COMMAND


Techincal Specification:
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE DEPTH0.422 INCHES MINIMUM AND 0.453 INCHES MAXIMUM FIRST FLANGE
FLANGE DEPTH0.422 INCHES MINIMUM AND 0.453 INCHES MAXIMUM SECOND FLANGE
FLANGE CONNECTING FACILITY AND QUANTITY4 THREADED HOLE SECOND FLANGE SECOND CONNECTION FACILITY
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE FIRST FLANGE FIRST CONNECTION FACILITY
FLANGE CONNECTING HOLE DIAMETER0.169 INCHES MINIMUM AND 0.174 INCHES MAXIMUM SECOND FLANGE SECOND CONNECTION FACILITY
FLANGE INSIDE WIDTH1.003 INCHES MINIMUM AND 1.006 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE WIDTH1.003 INCHES MINIMUM AND 1.006 INCHES MAXIMUM SECOND FLANGE
FLANGE INSIDE HEIGHT0.503 INCHES MINIMUM AND 0.506 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE HEIGHT0.503 INCHES MINIMUM AND 0.506 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE HEIGHT1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE HEIGHT1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE WIDTH1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE WIDTH1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM SECOND FLANGE
FLANGE QUANTITY2
FLANGE STYLECOVER TYPE FIRST FLANGE
FLANGE STYLECOVER TYPE SECOND FLANGE
FLEXIBILITYRIGID SINGLE TUBING SEGMENT
FSC APPLICATION DATAANTENNA RECEIVER TRANSMITTER GROUP MISSILE TRACKING
MATERIALBERYLLIUM OR COPPER ALL TUBING SEGMENT AND FLANGE
MAXIMUM OPERATING PRESSURE15.0 KILOGRAMS PER SQUARE CENTIMETER GAGE
NOMINAL THREAD SIZE0.164 INCHES SECOND FLANGE SECOND CONNECTION FACILITY
STYLE DESIGNATORSTRAIGHT TYPE
VOLTAGE STANDING WAVE RATIO1.10
WAVEGUIDE INSIDE HEIGHT0.400 INCHES NOMINAL
WAVEGUIDE INSIDE WIDTH0.900 INCHES NOMINAL
WAVEGUIDE LENGTH2.250 INCHES NOMINAL
WAVEGUIDE OUTSIDE HEIGHT0.500 INCHES NOMINAL
WAVEGUIDE OUTSIDE WIDTH1.000 INCHES NOMINAL
SURFACE TREATMENTCOPPER AND SILVER ALL TUBING SEGMENT AND FLANGE ALL SURFACES
THREAD DIRECTIONRIGHT-HAND SECOND FLANGE SECOND CONNECTION FACILITY
THREAD CLASS2B SECOND FLANGE SECOND CONNECTION FACILITY
THREAD SERIES DESIGNATORUNC SECOND FLANGE SECOND CONNECTION FACILITY
TUBING WALL CONSTRUCTION STYLESEAMLESS SINGLE TUBING SEGMENT