| STYLE DESIGNATOR | BEND TYPE |
| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
| FLANGE QUANTITY | 2 |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
| FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
| MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
| WAVEGUIDE LONGER OFFSET DISTANCE | 1.302 INCHES MINIMUM AND |
| 1.322 INCHES MAXIMUM |
| WAVEGUIDE OFFSET DISTANCE | 1.208 INCHES MINIMUM AND |
| 1.228 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 1.148 INCHES NOMINAL |
| WAVEGUIDE INSIDE WIDTH | 1.020 INCHES NOMINAL |
| WAVEGUIDE INSIDE HEIGHT | 0.510 INCHES NOMINAL |
| WAVEGUIDE OUTSIDE HEIGHT | 0.638 INCHES NOMINAL |
| BEND ANGLE IN DEG | 90.0 SINGLE BEND E-PLANE |
| SURFACE TREATMENT | ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| FLANGE CONNECTING HOLE DIAMETER | 0.180 INCHES NOMINAL ALL FLANGES ALL CONNECTION FACILITIES |
| MAXIMUM OPERATING PRESSURE | 10.0 POUNDS PER SQUARE INCH GAGE |
| INSERTION LOSS IN DECIBELS | 0.10 |
| VOLTAGE STANDING WAVE RATIO | 1.20 |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |