FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE QUANTITY | 2 |
FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
INSERTION LOSS IN DECIBELS | 0.09 |
III STYLE DESIGNATOR | OFFSET BEND TYPE |
PRECIOUS MATERIAL | SILVER |
PRECIOUS MATERIAL AND LOCATION | TUBING,INTERIOR SILVER |
PROPRIETARY CHARACTERISTICS | PACS |
MAXIMUM OPERATING PRESSURE | 20.0 POUNDS PER SQUARE INCH GAGE |
VOLTAGE STANDING WAVE RATIO | 1.20 |
WAVEGUIDE CENTER TO CENTER DISTANCE | 6.630 INCHES MINIMUM AND 6.690 INCHES MAXIMUM |
WAVEGUIDE LENGTH | 3.160 INCHES MINIMUM AND 3.220 INCHES MAXIMUM |
TUBING WALL CONSTRUCTION STYLE | CORRUGATED SINGLE TUBING SEGMENT |
CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM ALL FLANGES ALL CONNECTION FACILITIES AND 0.174 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |