CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR |
FLANGE DEPTH | 0.255 INCHES MINIMUM AND 0.260 INCHES MAXIMUM SINGLE FLANGE |
FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE CONNECTING HOLE DIAMETER | 0.127 INCHES MINIMUM AND 0.128 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE INSIDE HEIGHT | 0.134 INCHES MINIMUM AND 0.138 INCHES MAXIMUM SINGLE FLANGE |
FLANGE INSIDE WIDTH | 0.286 INCHES MINIMUM AND 0.290 INCHES MAXIMUM SINGLE FLANGE |
FLANGE OUTSIDE DIAMETER | 0.688 INCHES NOMINAL SINGLE FLANGE |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CONTACT TYPE ALL FLANGES |
FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
INSERTION LOSS IN DECIBELS | 1.25 |
MATERIAL | COPPER SINGLE TUBING SEGMENT |
SPECIAL FEATURES | FREQUENCY RANGE 18.0 TO 40.0 GHZ |
STYLE DESIGNATOR | STRAIGHT TYPE |
WAVEGUIDE INSIDE HEIGHT | 0.132 INCHES MINIMUM AND 0.136 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 0.286 INCHES MINIMUM AND 0.290 INCHES MAXIMUM |
WAVEGUIDE LENGTH | 29.200 INCHES MINIMUM AND 29.300 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE HEIGHT | 0.194 INCHES MINIMUM AND 0.219 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 0.348 INCHES MINIMUM AND 0.373 INCHES MAXIMUM |
SURFACE TREATMENT | LACQUER SINGLE TUBING SEGMENT AND FLANGE ALL SURFACES |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |