CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE DEPTH | 0.438 INCHES NOMINAL ALL FLANGES |
FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM AND 0.172 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE INSIDE WIDTH | 0.900 INCHES NOMINAL ALL FLANGES |
FLANGE INSIDE HEIGHT | 0.400 INCHES NOMINAL ALL FLANGES |
FLANGE OUTSIDE HEIGHT | 1.625 INCHES NOMINAL ALL FLANGES |
FLANGE OUTSIDE WIDTH | 1.625 INCHES NOMINAL ALL FLANGES |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CHOKE TYPE ALL FLANGES |
FLEXIBILITY | RIGID ALL TUBING SEGMENT |
FSC APPLICATION DATA | RADAR SET AN/APG-65 |
MATERIAL | ALUMINUM ALLOY 6061 ALL TUBING SEGMENT AND FLANGE |
VOLTAGE STANDING WAVE RATIO | 1.20 |
WAVEGUIDE INSIDE HEIGHT | 0.400 INCHES NOMINAL |
WAVEGUIDE INSIDE WIDTH | 0.900 INCHES NOMINAL |
WAVEGUIDE OUTSIDE HEIGHT | 0.500 INCHES NOMINAL |
WAVEGUIDE OUTSIDE WIDTH | 1.000 INCHES NOMINAL |
SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT AND FLANGE ALL SURFACES |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |