CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR DOUBLE INDENTED |
FLANGE CONNECTING FACILITY AND QUANTITY | 8 THREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY |
FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES NOMINAL FIRST FLANGE SINGLE CONNECTION FACILITY |
FLANGE DEPTH | 0.250 INCHES NOMINAL FIRST FLANGE |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CONTACT, DOUBLE RIDGE TYPE FIRST FLANGE |
FLANGE STYLE | CONTACT, DOUBLE RIDGE TYPE SECOND FLANGE |
FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
INSERTION LOSS IN DECIBELS | 0.15 |
MATERIAL | ALUMINUM ALL FLANGE |
MATERIAL | BERYLLIUM SINGLE TUBING SEGMENT |
III FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
III PRECIOUS MATERIAL AND LOCATION | WAVEGUIDE SURFACES SILVER |
III PRECIOUS MATERIAL | SILVER |
III STYLE DESIGNATOR | OFFSET BEND TYPE |
PROPRIETARY CHARACTERISTICS | PACS |
MAXIMUM OPERATING PRESSURE | 45.0 POUNDS PER SQUARE INCH GAGE |
SPECIAL FEATURES | 1ST FLANGE HAS TWO PIN,DOWELS; 2ND FLANGE HAS TWO HOLES FOR PIN,DOWELS |
SPECIFICATION/STANDARD DATA | 43999-LE413-0249 MANUFACTURERS SPECIFICATION CONTROL |
VOLTAGE STANDING WAVE RATIO | 1.25 |
WAVEGUIDE CENTER TO CENTER DISTANCE | 3.440 INCHES MINIMUM AND 3.560 INCHES MAXIMUM |
WAVEGUIDE LENGTH | 3.502 INCHES MINIMUM AND 3.622 INCHES MAXIMUM |
SURFACE TREATMENT | SILVER SINGLE TUBING SEGMENT ALL SURFACES |