5985-01-318-8091 WAVEGUIDE ASSEMBLY Index 5995-01-318-8093 CABLE ASSEMBLY,POWER,ELECTRICAL

National Stock Number:
5985-01-318-8092

Federal Supply Class:
5985

National Item Identification Number:
013188092

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
951431-543B150RAYTHEON COMPANY
951431-5449956RAYTHEON COMPANY
951431-5454X10RAYTHEON COMPANY


Techincal Specification:
BEND ANGLE IN DEG45.0 SECOND BEND E-PLANE
BEND ANGLE IN DEG45.0 THIRD BEND E-PLANE
BEND ANGLE IN DEG90.0 FIFTH BEND E-PLANE
BEND ANGLE IN DEG90.0 FIRST BEND H-PLANE
BEND ANGLE IN DEG90.0 FOURTH BEND H-PLANE
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE CONNECTING FACILITY AND QUANTITY8 THREADED HOLE(S) ALL FLANGES ALL CONNECTION FACILITIES
FLANGE DEPTH0.922 INCHES MINIMUM AND 0.953 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE HEIGHT0.867 INCHES MINIMUM AND 0.877 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE WIDTH1.867 INCHES MINIMUM AND 1.877 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE DIAMETER3.610 INCHES MINIMUM AND 3.640 INCHES MAXIMUM ALL FLANGES
FLANGE QUANTITY2
FLANGE STYLECHOKE TYPE ALL FLANGES
FLEXIBILITYRIGID ALL TUBING SEGMENT
FSC APPLICATION DATACOMMUNICATIONS EQUIPMENT
OPERATING PRESSURE15.0 POUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM
MATERIALALUMINUM ALLOY 6061 ALL TUBING SEGMENT AND FLANGE
NOMINAL THREAD SIZE0.190 INCHES ALL FLANGES ALL CONNECTION FACILITIES
THREAD SERIES DESIGNATORUNF ALL FLANGES ALL CONNECTION FACILITIES
TUBING WALL CONSTRUCTION STYLESEAMLESS ALL TUBING SEGMENT
VOLTAGE STANDING WAVE RATIO1.12
WAVEGUIDE FIFTH LEG LENGTH15.440 INCHES MINIMUM AND 15.560 INCHES MAXIMUM
WAVEGUIDE FIRST LEG LENGTH2.250 INCHES MINIMUM AND 2.370 INCHES MAXIMUM
WAVEGUIDE FOURTH LEG LENGTH38.940 INCHES MINIMUM AND 39.060 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.867 INCHES MINIMUM AND 0.877 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.995 INCHES MINIMUM AND 1.005 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM
WAVEGUIDE SECOND LEG LENGTH4.320 INCHES MINIMUM AND 4.440 INCHES MAXIMUM
WAVEGUIDE SIXTH LEG LENGTH2.190 INCHES MINIMUM AND 2.310 INCHES MAXIMUM
WAVEGUIDE THIRD LEG LENGTH1.940 INCHES MINIMUM AND 2.060 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH1.867 INCHES MINIMUM AND 1.877 INCHES MAXIMUM
STYLE DESIGNATORFIVE BEND TYPE
SURFACE TREATMENTCHROMATE ALL TUBING SEGMENT AND FLANGE ALL SURFACES
THREAD DIRECTIONRIGHT-HAND ALL FLANGES ALL CONNECTION FACILITIES
THREAD CLASS2B ALL FLANGES ALL CONNECTION FACILITIES