CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE DEPTH | 0.734 INCHES MINIMUM AND 0.766 INCHES MAXIMUM ALL FLANGES |
FLANGE CONNECTING FACILITY AND QUANTITY | 6 THREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE INSIDE WIDTH | 1.368 INCHES MINIMUM AND 1.376 INCHES MAXIMUM ALL FLANGES |
FLANGE INSIDE HEIGHT | 0.618 INCHES MINIMUM AND 0.626 INCHES MAXIMUM ALL FLANGES |
FLANGE OUTSIDE DIAMETER | 3.109 INCHES MINIMUM AND 3.141 INCHES MAXIMUM ALL FLANGES |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CHOKE TYPE ALL FLANGES |
FLEXIBILITY | RIGID ALL TUBING SEGMENT |
FSC APPLICATION DATA | RADAR EQUIPMENT |
INSERTION LOSS IN DECIBELS | 0.10 |
MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
MAXIMUM OPERATING PRESSURE | 45.0 POUNDS PER SQUARE INCH GAGE |
NOMINAL THREAD SIZE | 0.190 INCHES ALL FLANGES ALL CONNECTION FACILITIES |
SPECIAL FEATURES | FREQUENCY RANGE 6.89 GHZ TO 8.45 GHZ |
STYLE DESIGNATOR | BEND TYPE |
VOLTAGE STANDING WAVE RATIO | 1.12 |
WAVEGUIDE INSIDE HEIGHT | 0.618 INCHES MINIMUM AND 0.626 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 1.368 INCHES MINIMUM AND 1.376 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 1.496 INCHES MINIMUM AND 1.504 INCHES MAXIMUM |
WAVEGUIDE LONGER OFFSET DISTANCE | 11.460 INCHES MINIMUM AND 11.520 INCHES MAXIMUM |
WAVEGUIDE OFFSET DISTANCE | 3.800 INCHES MINIMUM AND 3.860 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE HEIGHT | 0.746 INCHES MINIMUM AND 0.754 INCHES MAXIMUM |
SURFACE TREATMENT | PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
THREAD DIRECTION | RIGHT-HAND ALL FLANGES ALL CONNECTION FACILITIES |
THREAD CLASS | 2B ALL FLANGES ALL CONNECTION FACILITIES |
THREAD SERIES DESIGNATOR | UNF ALL FLANGES ALL CONNECTION FACILITIES |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |