CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE DEPTH | 0.415 INCHES MINIMUM AND 0.445 INCHES MAXIMUM FIRST FLANGE |
FLANGE DEPTH | 0.610 INCHES MINIMUM AND 0.640 INCHES MAXIMUM SECOND FLANGE |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
FLANGE CONNECTING HOLE DIAMETER | 0.164 INCHES MINIMUM AND 0.174 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
FLANGE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM SECOND FLANGE |
FLANGE INSIDE WIDTH | 1.250 INCHES MINIMUM AND 1.256 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM SECOND FLANGE |
FLANGE INSIDE HEIGHT | 0.617 INCHES MINIMUM AND 0.623 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM SECOND FLANGE |
FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM SECOND FLANGE |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CHOKE TYPE SECOND FLANGE |
FLANGE STYLE | COVER TYPE FIRST FLANGE |
FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
INSERTION LOSS IN DECIBELS | 0.10 |
MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
MAXIMUM OPERATING PRESSURE | 25.0 POUNDS PER SQUARE INCH GAGE |
NOMINAL THREAD SIZE | 0.164 INCHES SECOND FLANGE ALL CONNECTION FACILITIES |
STYLE DESIGNATOR | BEND TYPE |
VOLTAGE STANDING WAVE RATIO | 1.12 |
WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |
WAVEGUIDE LONGER OFFSET DISTANCE | 7.440 INCHES NOMINAL |
WAVEGUIDE OFFSET DISTANCE | 1.560 INCHES NOMINAL |
WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
SUPPLEMENTARY FEATURES | FREQUENCY 8.49 TO 9.61 GHZ |
SURFACE TREATMENT | PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
THREAD DIRECTION | RIGHT-HAND SECOND FLANGE ALL CONNECTION FACILITIES |
THREAD CLASS | 2B SECOND FLANGE ALL CONNECTION FACILITIES |
THREAD SERIES DESIGNATOR | UNC SECOND FLANGE ALL CONNECTION FACILITIES |
TUBING TWIST ANGLE IN DEG | 90.0 SINGLE TUBING SEGMENT |
TUBING TWIST TYPE | TWISTABLE SINGLE TUBING SEGMENT |
TUBING WALL CONSTRUCTION STYLE | CORRUGATED SINGLE TUBING SEGMENT |