National Stock Number: 6110-01-148-4697
Federal Supply Class: 6110
National Item Identification Number: 011484697
Description: STARTER,MOTOR
Detail: A DEVICE PRIMARILY DESIGNED TO CONTROL THE SUPPLY CIRCUIT(S) OF A MOTOR IN ORDER TO ACCELERATE THE MOTOR FROM REST TO NORMAL SPEED. INCLUDES MANUAL STARTERS WITH OVERLOAD PROTECTION AND MANUAL, AUTOMATIC OR SEMIAUTOMATIC STARTERS CONSISTING OF COMBINATIONS OF ITEMS SUCH AS RELAYS, RESISTORS, SWITCHES, CIRCUIT BREAKERS, ETC. EXCLUDES RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (AS MODIFIED) AND RELAY (AS MODIFIED). FOR DEVICES, WHICH IN ADDITION TO STARTING AND STOPPING, REVERSE, SELECT AND/OR REGULATE THE SPEED OF A MOTOR, SEE CONTROLLER (AS MODIFIED).
|
Manufacturer Information:
6962CD4871 | 27192 | DRS NAVAL POWER SYSTEMS INC | 6962ED2533A2 | 27192 | DRS NAVAL POWER SYSTEMS INC | MIL-C-2212 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | MIL-DTL-2212 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M |
|
Techincal Specification:
DUTY CYCLE | CONTINUOUS | ENCLOSURE FEATURE | DRIPPROOF | AC VOLTAGE RATING | 440.0 VOLTS NOMINAL | ACTUATION METHOD | MAGNETIC | ACTUATOR VOLTAGE | 110.0 AC | AMBIENT TEMP | 50.0 CELSIUS | CONTROL TYPE | LOCAL OR REMOTE | FUSE ACCOMMODATION QUANTITY | 6 | FUSE CURRENT RATING IN AMPS | 10.0 | FEATURES PROVIDED | CIRCUIT PROTECTION FUSE | FREQUENCY IN HERTZ | 60.0 | FREQUENCY RATING | 60.0 HERTZ NOMINAL | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DRIPPROOF | LOAD PROTECTION TYPE | OVERLOAD AND UNDERVOLTAGE | OVERALL HEIGHT | 10.390 INCHES NOMINAL | OVERALL LENGTH | 26.125 INCHES NOMINAL | OVERALL WIDTH | 18.109 INCHES NOMINAL | MOUNTING CONFIGURATION | SIX 17/32 IN. DIA HOLES;RECTANGULAR ARRANGEMENT; 2 ROWS OF 3 EA SPACED 7-1/4 IN. C TO C; 24 IN. SPACING BETWEEN ROW CENTERLINES | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD | OPERATING VOLTAGE CHARACTERISTIC | FULL | PERFORMANCE TYPE | AUTOMATIC OR MANUAL | PHASE | THREE | POWER RATING | 50.000 HORSEPOWER | SIZE DESIGNATOR | 3 | SPEED ADJUSTMENTS | 0 TO FULL SPEED | SPECIAL FEATURES | PROVIDES FACILITY FOR SWITCHING ELECTRO-HYDRAULIC POWER PUMP TO ALTERNATE RAISE-LOWER MODES OF OPERATION AS DISTINCT FROM MOTOR REVERSAL | SWITCH FUNCTIONAL POSITIONS | EMERGENCY RUN AND LOWER AND REMOTE CONTROL OFF AND RAISE AND REMOTE CONTROL ON AND START AND STOP |
|
|