INPUT VOLTAGE RATING | 180.0 AC VOLTS MINIMUM AND |
| 264.0 AC VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
| 90.0 AC VOLTS MINIMUM AND |
| 132.0 AC VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
OVERALL LENGTH | 11.000 INCHES NOMINAL |
OUTPUT VOLTAGE RATING | 22.8 DC VOLTS MINIMUM AND |
| 25.2 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
| 14.2 DC VOLTS MINIMUM AND |
| 15.7 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
| 5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
| -14.2 DC VOLTS MINIMUM AND |
| -15.7 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
OUTPUT CURRENT RATING | 0.0 DC AMPERES MINIMUM AND |
| 2.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
| 0.0 DC AMPERES MINIMUM AND |
| 6.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
| 1.1 DC AMPERES MINIMUM AND |
| 11.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM AND |
| 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
POWER SUPPLY EFFICIENCY LINE | 70.0 |
MAXIMUM OPERATING ALTITUDE RATING | 10000.0 FEET |
OVERALL WIDTH | 5.800 INCHES NOMINAL |
OVERALL HEIGHT | 2.510 INCHES NOMINAL |
OPERATING AMBIENT TEMP RANGE | -0.1 TO 50.0 DEG CELSIUS |
FEATURES PROVIDED | CIRCUIT OVERLOAD PROTECTION DEVICE AND |
| CURRENT REGULATOR CIRCUIT |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 23934 |
DESIGN CONTROL REFERENCE | EVD-165-4009 |