National Stock Number: 6130-01-281-8609
Federal Supply Class: 6130
National Item Identification Number: 012818609
Description: POWER SUPPLY
Detail: A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. EXCLUDES BATTERY CHARGERS; ROTATING MACHINERY TYPES; SUCH AS MOTOR GENERATORS AND DYNAMOTORS, POWER SUPPLY, CAUTERY APPARATUS; POWER SUPPLY, ELECTRODIAGNOSTIC INSTRUMENTS, AND POWER SUPPLY, MOBILE RESPIRATOR.
|
Manufacturer Information:
31554000-1 | 60642 | ADVANCED CONVERSION TECHNOLOGY INC | H-16FA | 08748 | ELDEC AEROSPACE CORP | H-16FA700 | 08748 | ELDEC AEROSPACE CORP |
|
Techincal Specification:
ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING | INPUT CURRENT RATING | 220.0 DC MILLIAMPERES MINIMUM AND 800.0 DC MILLIAMPERES MAXIMUM SINGLE OPERATING POWER RQMT | INPUT VOLTAGE RATING | 28.0 DC VOLTS NOMINAL SINGLE OPERATING POWER RQMT | OUTPUT CONNECTION QUANTITY | 2 SINGLE POWER OUTPUT | OUTPUT CONNECTION TYPE | CONNECTOR, RECEPTACLE SINGLE POWER OUTPUT | OUTPUT CURRENT RATING | 500.0 DC MICROAMPERES NOMINAL SINGLE POWER OUTPUT | OUTPUT VOLTAGE RATING | 0.0 DC KILOVOLTS MINIMUM AND 16.0 DC KILOVOLTS MAXIMUM SINGLE POWER OUTPUT | OVERALL HEIGHT | 2.000 INCHES NOMINAL | OVERALL LENGTH | 5.440 INCHES NOMINAL | OVERALL WIDTH | 3.130 INCHES NOMINAL | MAXIMUM OPERATING ALTITUDE RATING | 50000.0 FEET | OPERATING AMBIENT TEMP RANGE | -55.0 TO 71.0 CELSIUS |
|
|