INPUT VOLTAGE RATING | 115.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT |
OUTPUT VOLTAGE RATING | 65.0 DC VOLTS MINIMUM AND |
| 105.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
| 45.0 DC VOLTS MINIMUM AND |
| 95.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
OUTPUT CURRENT RATING | 0.75 DC AMPERES NOMINAL 1ST POWER OUTPUT |
| 2.00 DC AMPERES NOMINAL 2ND POWER OUTPUT |
POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | CONSTANT CURRENT 1ST POWER OUTPUT |
| CONSTANT CURRENT 2ND POWER OUTPUT |
RIPPLE VOLTAGE AT FULL LOAD | 4.0 MILLIVOLTS RMS 1ST POWER OUTPUT |
| 4.0 MILLIVOLTS RMS 2ND POWER OUTPUT |
ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
INPUT FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT |
INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
INPUT CONNECTION TYPE | CONNECTOR, PLUG SINGLE OPERATING POWER RQMT |
INPUT CONNECTION QUANTITY | 1 SINGLE OPERATING POWER RQMT |
VENTILATION DESIGN TYPE | SINGLE FAN |
OVERALL WIDTH | 7.730 INCHES NOMINAL |
OVERALL HEIGHT | 4.980 INCHES NOMINAL |
OPERATING AMBIENT TEMP RANGE | 0.1 TO 71.0 DEG CELSIUS |
FEATURES PROVIDED | OVER TEMPERATURE PROTECTION AND |
| OVER CURRENT PROTECTOR AND |
| OVER VOLTAGE PROTECTOR |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 9Y580 |
DESIGN CONTROL REFERENCE | 102186-2 |