ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
BATTERY FEATURE AND TYPE | RECHARGEABLE LEAD ACID CELL |
BATTERY POWER SUPPLY EMERGENCY OPERATING TIME | 6.0 |
BATTERY RECOVERY TIME | 180.0 |
BATTERY SWITCHING TIME | TWO MILLISECONDS |
FEATURES PROVIDED | BATTERY CHARGER AND CIRCUIT BREAKER AND CURRENT REGULATOR CIRCUIT AND EMI FILTER AND INDICATOR LIGHT AND OVER VOLTAGE PROTECTOR AND PROGRAMMABLE |
INPUT CONNECTION QUANTITY | 2 SINGLE OPERATING POWER RQMT |
INPUT CONNECTION TYPE | CONNECTOR, PLUG SINGLE OPERATING POWER RQMT |
INPUT VOLTAGE RATING | 120.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT |
INPUT FREQUENCY RATING | 47.5 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
INSTALLATION DESIGN | CABINET WITH COMPLETE HARDWARE |
OVERALL HEIGHT | 6.600 INCHES NOMINAL |
OVERALL LENGTH | 14.500 INCHES NOMINAL |
OVERALL WIDTH | 4.700 INCHES NOMINAL |
MAXIMUM OPERATING ALTITUDE RATING | 10000.0 FEET |
OPERATING AMBIENT TEMP RANGE | +32.0 TO 104.0 FAHRENHEIT |
OUTPUT CONNECTION QUANTITY | 6 SINGLE POWER OUTPUT |
OUTPUT CONNECTION TYPE | RECEPTACLE, ELECTRICAL SINGLE POWER OUTPUT |
OUTPUT CONTROL QUANTITY | 2 SINGLE POWER OUTPUT |
OUTPUT CONTROL TYPE | VOLTAGE RANGE SINGLE POWER OUTPUT |
OUTPUT CURRENT RATING | 650.0 AC VOLT-AMPERE MAXIMUM SINGLE POWER OUTPUT |
OUTPUT FREQUENCY RATING | 49.9 HERTZ MINIMUM AND 60.1 HERTZ MAXIMUM SINGLE POWER OUTPUT |
OUTPUT VOLTAGE RATING | 115.0 AC VOLTS NOMINAL SINGLE POWER OUTPUT |
OUTPUT PHASE | SINGLE SINGLE POWER OUTPUT |
OUTPUT WATTAGE RATING | 410.0 WATTS MAXIMUM SINGLE POWER OUTPUT |
POWER SUPPLIES PROGRAMMED PER SYSTEM | 2 |
POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | LIMITING VOLTAGE SINGLE POWER OUTPUT |
PROGRAM COMPATIBILITY | APPLE, IBM COMPATIBLE OR UNIX PERSONAL COMPUTERS |
SPECIAL FEATURES | PROGRAMMING TO AUTOMATICALLY INCREASE OUTPUT UP TO 30 PERCENT WHEN INPUT FALLS BETWEEN 81 VAC TO 106 VAC; AUTOMATICALLY DECREASES OUTPUT UP TO 15 PERCENT WHEN INPUT IS BETWEEN 127 VAC AND 143 VAC; OVERLOAD PROTECTION ON BATTERY-INTERNAL CURRENT LIMITING AND ON LINE CIRCUIT BREAKER; MODEM/10 BASE-T/100 BASE-TX NETWORK CABLE PORT USING SINGLE LINE (2 WIRE, RJ11) OR NETWORK (UTP, RJ45) COMPATIBLE JACKS; BATTERY IS USER REPLACEABLE, HOT SWAPPABLE, SEALED, AND MAINTENANCE FREE; 14 DAY AUTO SELF TEST OF ALL INTERNAL COMPONENTS; LEDS INDICATE WHEN ON LINE, ON BATTERY, UPS OVERLOAD, AND REPLACE BATTERY; ALARMS FOR ON BATTERY, LOW BATTERY, AND UPS OVERLOAD; DATA SAVING UNATTENDED SHUTDOWN, ADVANCED POWER MANAGEMENT AND DIAGNOSTIC SOFTWARE INCLUDED; DB 9 SERIAL INTERFACE PORT; OUTPUT VOLTAGE ON BATTERY IS STEPPED APPROXIMATION TO SINE WAVE OUTPUT AT 115 VAC PLUS OR MINUS 8 PERCENT |