Description:
POWER SUPPLY

Detail:
A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. EXCLUDES BATTERY CHARGERS; ROTATING MACHINERY TYPES; SUCH AS MOTOR GENERATORS AND DYNAMOTORS, POWER SUPPLY, CAUTERY APPARATUS; POWER SUPPLY, ELECTRODIAGNOSTIC INSTRUMENTS, AND POWER SUPPLY, MOBILE RESPIRATOR.


Manufacturer Information:
81F2140Z3G7NEWARK CORPORATION DIV NEWARK DBA NEWARK
81F2141VZM8NEWARK CORPORATION
86-24-2620RJ90SOLA ELECTRIC A UNIT OF GENERAL SIGNAL CORP
86-24-26211196DRECO INC


Techincal Specification:
INPUT VOLTAGE RATING90.0 AC VOLTS MINIMUM AND
132.0 AC VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
180.0 AC VOLTS MINIMUM AND
264.0 AC VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
OVERALL LENGTH9.150 INCHES NOMINAL
OUTPUT VOLTAGE RATING24.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT
OUTPUT CURRENT RATING6.3 DC AMPERES NOMINAL SINGLE POWER OUTPUT
POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICSLIMITING CURRENT AND
LIMITING VOLTAGE SINGLE POWER OUTPUT
ELECTRICAL POWER SOURCE RELATIONSHIPOPERATING
INPUT CURRENT RATING16.0 AC AMPERES MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING47.0 HERTZ MINIMUM AND
400.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
47.0 HERTZ MINIMUM AND
400.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
INPUT PHASESINGLE 1ST ALTERNATE OPERATING POWER RQMT
SINGLE 2ND ALTERNATE OPERATING POWER RQMT
POWER SUPPLY EFFICIENCY LINE65.0
OVERALL WIDTH5.000 INCHES NOMINAL
OVERALL HEIGHT2.500 INCHES NOMINAL
OPERATING AMBIENT TEMP RANGE0.1 TO 40.0 DEG CELSIUS