Description:
POWER SUPPLY

Detail:
A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. EXCLUDES BATTERY CHARGERS; ROTATING MACHINERY TYPES; SUCH AS MOTOR GENERATORS AND DYNAMOTORS, POWER SUPPLY, CAUTERY APPARATUS; POWER SUPPLY, ELECTRODIAGNOSTIC INSTRUMENTS, AND POWER SUPPLY, MOBILE RESPIRATOR.


Manufacturer Information:
42-384427192DRS NAVAL POWER SYSTEMS INC
PSX25AS2815420LOGITEK INC


Techincal Specification:
INPUT VOLTAGE RATING110.0 AC VOLTS NOMINAL 1ST OPERATING POWER RQMT
220.0 AC VOLTS NOMINAL 2ND OPERATING POWER RQMT
120.0 DC VOLTS MINIMUM AND
320.0 DC VOLTS MAXIMUM 3RD OPERATING POWER RQMT
OVERALL LENGTH3.400 INCHES NOMINAL
OUTPUT VOLTAGE RATING28.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT
OUTPUT CURRENT RATING0.8 DC AMPERES MAXIMUM SINGLE POWER OUTPUT
OUTPUT WATTAGE RATING25.0 WATTS NOMINAL SINGLE POWER OUTPUT
POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICSCONSTANT CURRENT SINGLE POWER OUTPUT
OUTPUT CONTROL TYPECURRENT LIMIT SINGLE POWER OUTPUT
OUTPUT CONNECTION QUANTITY1 SINGLE POWER OUTPUT
OUTPUT CONNECTION TYPECONNECTOR, PLUG SINGLE POWER OUTPUT
ELECTRICAL POWER SOURCE RELATIONSHIPOPERATING
INPUT FREQUENCY RATING47.0 HERTZ MINIMUM AND
440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT
47.0 HERTZ MINIMUM AND
440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT
INPUT PHASESINGLE 1ST OPERATING POWER RQMT
SINGLE 2ND OPERATING POWER RQMT
SINGLE 3RD OPERATING POWER RQMT
INPUT CONNECTION TYPECONNECTOR, PLUG 1ST OPERATING POWER RQMT
CONNECTOR, PLUG 2ND OPERATING POWER RQMT
CONNECTOR, PLUG 3RD OPERATING POWER RQMT
INPUT CONNECTION QUANTITY1 1ST OPERATING POWER RQMT
1 2ND OPERATING POWER RQMT
1 3RD OPERATING POWER RQMT
POWER SUPPLY EFFICIENCY LINE75.0
ENVIRONMENTAL PROTECTIONDUSTPROOF AND
FUNGUS PROOF AND
SALT SPRAY RESISTANT
MAXIMUM OPERATING ALTITUDE RATING70000.0 FEET
OVERALL WIDTH2.800 INCHES NOMINAL
OVERALL HEIGHT0.800 INCHES NOMINAL
OPERATING AMBIENT TEMP RANGE-55.0 TO 100.0 DEG CELSIUS