INPUT VOLTAGE RATING | 120.0 DC VOLTS MINIMUM AND |
| 360.0 DC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
| 360.0 DC VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
| 120.0 DC VOLTS MINIMUM AND |
| 360.0 DC VOLTS MAXIMUM 3RD OPERATING POWER RQMT |
OVERALL LENGTH | 259.3 MILLIMETERS NOMINAL |
OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
| 12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
| 12.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
OUTPUT CURRENT RATING | 50.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
| 12.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
| 9.3 DC AMPERES NOMINAL 3RD POWER OUTPUT |
RECTIFICATION METHOD | CONVERTER DC TO DC |
OUTPUT FREQUENCY RATING | 190.0 KILOHERTZ NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
OUTPUT WATTAGE RATING | 350.0 WATTS NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
RIPPLE VOLTAGE AT FULL LOAD | 50.0 MILLIVOLTS PEAK MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
INPUT CURRENT RATING | 25.0 DC AMPERES NOMINAL 1ST OPERATING POWER RQMT |
| 25.0 DC AMPERES NOMINAL 2ND OPERATING POWER RQMT |
| 25.0 DC AMPERES NOMINAL 3RD OPERATING POWER RQMT |
INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM AND |
| 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
| 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
| 47.0 HERTZ MINIMUM AND |
| 440.0 HERTZ MAXIMUM 3RD OPERATING POWER RQMT |
VENTILATION DESIGN TYPE | DUAL FAN |
OVERALL WIDTH | 126.5 MILLIMETERS NOMINAL |
OVERALL HEIGHT | 63.2 MILLIMETERS NOMINAL |
FEATURES PROVIDED | OVER VOLTAGE PROTECTOR AND |
| OVER CURRENT PROTECTOR AND |
| OVER TEMPERATURE PROTECTION AND |
| CIRCUIT OVERLOAD PROTECTION DEVICE AND |
| REMOTE ERROR SENSING CAPABILITY |
PART NAME ASSIGNED BY CONTROLLING AGENCY | SIRIUS 350 WATT MULTI OUTPUT POWER SUPPLY |