ELECTRICAL RESISTANCE | 95.0 OHMS IMPEDANCE |
CONDUCTOR ARRANGEMENT AND QUANTITY | 1 TWIN-AXIAL TWISTED |
CONDUCTOR QUANTITY | 2 |
CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CROSS SECTION OUTSIDE DIAMETER | 0.490 INCHES NOMINAL |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
MATERIAL | ALUMINUM ALLOY 6TH POSITION ARMOR CABLE |
MATERIAL | COPPER 3RD POSITION SHIELD BRAID, METALLIC CABLE |
MATERIAL | COPPER 4TH POSITION SHIELD BRAID, METALLIC CABLE |
MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATERIAL | PLASTIC POLYVINYL CHLORIDE (PVC) 5TH POSITION JACKET CABLE |
MATERIAL | PLASTIC POLYETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
MATERIAL | PLASTIC POLYETHYLENE 2ND POSITION JACKET CABLE |
NOMINAL CAPACITANCE IN PICOFARADS | 17.4 PER FOOT |
ROUND CONDUCTOR SIZE | 18 AWG ALL CONDUCTORS |
SPECIAL FEATURES | ONE STRAND OF ONE CONDUCTOR SHALL BE TINNED COPPER FOR IDENTIFICATION |
VOLTAGE RATING | 750.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
STRAND AWG SIZE PER CONDUCTOR | 26 ALL CONDUCTORS |
STRAND QUANTITY PER CONDUCTOR | 7 ALL CONDUCTORS |
SURFACE TREATMENT | TIN 3RD POSITION SHIELD BRAID, METALLIC CABLE |
SURFACE TREATMENT | TIN 4TH POSITION SHIELD BRAID, METALLIC CABLE |