6145-00-834-8740 CABLE,POWER,ELECTRICAL Index 6145-00-834-8744 CABLE,POWER,ELECTRICAL

National Stock Number:
6145-00-834-8741

Federal Supply Class:
6145

National Item Identification Number:
008348741

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
A-A-5954458536FEDERAL COMMERCIAL ITEM DESCRIPTION PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
AA59544RHW06CE2/10SRFC58536FEDERAL COMMERCIAL ITEM DESCRIPTION PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
RHW06CE2/10SRFC58536FEDERAL COMMERCIAL ITEM DESCRIPTION PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
J-C-30RHW06CE2/10SRFC81348FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC


Techincal Specification:
CONDUCTOR QUANTITY2
CONDUCTOR FORMSOLID ALL CONDUCTORS
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
RUBBER SYNTHETIC 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATERIAL DOCUMENT AND CLASSIFICATIONQQ-W-343,SOFT FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE10 AWG ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY1 PARALLEL PAIR
COLORBLACK 1ST POSITION COVER FIRST CONDUCTOR
WHITE 2ND POSITION COVER SECOND CONDUCTOR
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLEOVAL
CROSS-SECTIONAL HEIGHT0.270 INCHES NOMINAL
CROSS-SECTIONAL WIDTH0.490 INCHES NOMINAL
TEMP RATING75.0 DEG CELSIUS
SPEC/STD CONTROLLING DATA
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCEA-A-59544
MANUFACTURERS CODE58536
DEFINITIVE GOVERNMENT SPEC/STD REFERENCEAA59544RHW06CE2/10SRFC


Click here to Register for Free 30-day Trial