6145-01-229-8297 WIRE,ELECTRICAL Index 6145-01-229-8299 WIRE,ELECTRICAL

National Stock Number:
6145-01-229-8298

Federal Supply Class:
6145

National Item Identification Number:
012298298

Description:
WIRE,ELECTRICAL

Detail:
A single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. It may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. refers to buld quantities only. For items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see WIRE,(as modified), Includes Litz wire and insulated/uninsulated armored, and ground wire. Excludes BRAID, WIRE; FUSE WIRE; RESISTANCE WIRE and MAGNET WIRE.


Manufacturer Information:
C6986-24A9981755LOCKHEED MARTIN CORPORATION
XVB24U,WHITE3ET41RSCC WIRE & CABLE LLC
XVB24U,WHITE90484RSCC WIRE & CABLE LLC


Techincal Specification:
COLORWHITE 1ST POSITION COVER SINGLE CONDUCTOR
CONDUCTOR FORMSOLID SINGLE CONDUCTOR
CROSS SECTION OUTSIDE DIAMETER0.042 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR SINGLE CONDUCTOR
MATERIALCOPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR SINGLE CONDUCTOR
MATERIALPLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
PROPRIETARY CHARACTERISTICSPACS
ROUND CONDUCTOR SIZE24 AWG SINGLE CONDUCTOR
SPECIAL FEATURESPRIMARY INSULATION IS IRRADIATED AND CROSS-LINKED
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR
SURFACE TREATMENTTIN CORE CONDUCTOR SINGLE CONDUCTOR
TEMP RATING-55.0 DEG CELSIUS AND 105.0 DEG CELSIUS