7690-01-475-1130 MARKER,IDENTIFICATION Index 5360-01-475-1133 SPRING,HELICAL,COMPRESSION

National Stock Number:
6145-01-475-1131

Federal Supply Class:
6145

National Item Identification Number:
014751131

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
5MD1-18A4-UN8V613THE BOEING COMPANY
M27500-18WK4U0081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M27500B18WK4U001P787NATIONAL ELECTRICAL MFRS ASSN DBA NEMA
M27500B18WK4U0081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-2750081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-DTL-2750081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
NEMA WC275001P787NATIONAL ELECTRICAL MFRS ASSN DBA NEMA
NEMA-WC275001P787NATIONAL ELECTRICAL MFRS ASSN DBA NEMA


Techincal Specification:
COLORGREEN CORE CONDUCTOR FOURTH CONDUCTOR
COLORBLUE CORE CONDUCTOR SECOND CONDUCTOR
COLORYELLOW CORE CONDUCTOR THIRD CONDUCTOR
COLORRED CORE CONDUCTOR FIRST CONDUCTOR
CONDUCTOR QUANTITY4
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CRITICALITY CODE JUSTIFICATIONFEAT
CROSS SECTION OUTSIDE DIAMETER0.061 INCHES MINIMUM AND 0.065 INCHES MAXIMUM
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATERIALPLASTIC POLYIMIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATERIALPLASTIC POLYTETRAFLUOROETHYLENE 2ND POSITION SECONDARY INSULATION ALL CONDUCTORS
ROUND CONDUCTOR SIZE18 AWG ALL CONDUCTORS
SPECIAL FEATURESWEAPON SYSTEM ESSENTIAL
STRAND AWG SIZE PER CONDUCTOR30 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS
SURFACE TREATMENTNICKEL CORE CONDUCTOR ALL CONDUCTORS
TEMP RATING-65.0 CELSIUS AND 260.0 CELSIUS