CONDUCTOR QUANTITY | 66 |
CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
MATERIAL | PLASTIC 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
| RUBBER NATURAL OR |
| RUBBER SYNTHETIC 1ST POSITION JACKET CABLE |
ROUND CONDUCTOR SIZE | 16 AWG ALL CONDUCTORS |
CONDUCTOR ARRANGEMENT AND QUANTITY | 66 SINGLES |
COLOR CODING DOCUMENT | 21-52915-1205 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
STYLE DESIGNATOR | JACK AND EXTERNAL CONNECTOR |
OVERALL LENGTH | 34.500 FEET |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
CROSS SECTION OUTSIDE DIAMETER | 1.418 INCHES NOMINAL |
TERMINATION TYPE | CONNECTOR RECEPTACLE BOTH ENDS ALL CONDUCTORS |
TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | BACC45DS20D07P 1ST END ALL CONDUCTORS |
| BACC45DS20D07S 2ND END ALL CONDUCTORS |
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 81205 1ST END ALL CONDUCTORS |
| 81205 2ND END ALL CONDUCTORS |
SPECIAL FEATURES | DESIGN ANALYSIS |
CRITICALITY CODE JUSTIFICATION | FEAT |
NUCLEAR HARDNESS CRITICAL FEATURE | HARDENED |
FSC APPLICATION DATA | CABLE ASSEMBLY SET,LAUNCH CONTROL |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 81205 |
DESIGN CONTROL REFERENCE | 21-52915-2031 |