COLOR CODING DOCUMENT | 25-32849-81205 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)25-32849-81205 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
CONDUCTOR FORM | STRANDED ALL CONDUCTORSSTRANDED ALL CONDUCTORS |
CONDUCTOR QUANTITY | 66 |
CONDUCTOR SEQUENCE WITHIN GROUPS | FIRST CONDUCTOR AND FIRST CONDUCTOR AND SECOND CONDUCTOR AND SECOND CONDUCTOR AND THIRD CONDUCTOR AND THIRD CONDUCTOR AND FOURTH CONDUCTOR FIRST GROUPFOURTH CONDUCTOR FIRST GROUP |
CONDUCTOR SEQUENCE WITHIN GROUPS | FIFTH CONDUCTOR AND FIFTH CONDUCTOR AND SIXTH CONDUCTOR SECOND GROUPSIXTH CONDUCTOR SECOND GROUP |
CONDUCTOR ARRANGEMENT AND QUANTITY | 1 QUADS AND 1 QUADS AND 1 TWISTED PAIR1 TWISTED PAIR |
CROSS SECTION OUTSIDE DIAMETER | 0.740 INCHES NOMINAL0.740 INCHES NOMINAL |
CROSS-SECTIONAL SHAPE STYLE | ROUNDROUND |
FSC APPLICATION DATA | GUIDED MISSILE LAUNCHING CONTROL GROUPS |
INDIVIDUAL CONDUCTOR LENGTH | 10.000 INCHES NOMINAL SECOND END ALL CONDUCTORS10.000 INCHES NOMINAL SECOND END ALL CONDUCTORS |
MATERIAL DOCUMENT AND CLASSIFICATION | AMIL-W-76,TYPR HF MIL SPEC 1ST MATERIAL RESPONSE FIRST POSITION PRIMARY INSULATION ALL CONDUCTORSMIL-W-76. TYPE HF FED SPEC SINGLE MATERIAL RESPONSE SINGLE ROW SIXTH POSITION VERTICAL VERTICAL SPLIT DISPLAY DIVISION A |
MATERIAL DOCUMENT AND CLASSIFICATION | MIL-W-76. TYPE HF FED SPEC SINGLE MATERIAL RESPONSE SECOND POSITION JACKET ALL CONDUCTORSAMIL-W-76,TYPR HF MIL SPEC 1ST MATERIAL RESPONSE FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS |
MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORSCOPPER CORE CONDUCTOR ALL CONDUCTORS |
MATERIAL | PLASTIC POLYAMIDE (NYLON) FIRST POSITION PRIMARY INSULATION ALL CONDUCTORSPLASTIC POLYAMIDE (NYLON) FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS |
MATERIAL | PLASTIC POLYAMIDE (NYLON) SECOND POSITION JACKET ALL CONDUCTORSPLASTIC POLYAMIDE (NYLON) SECOND POSITION JACKET ALL CONDUCTORS |
OVERALL LENGTH | 33.583 FEET33.583 FEET |
ROUND CONDUCTOR SIZE | 16 AWG ALL CONDUCTORS16 AWG ALL CONDUCTORS |
STRAND AWG SIZE PER CONDUCTOR | 29 ALL CONDUCTORS29 ALL CONDUCTORS |
STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS19 ALL CONDUCTORS |
STYLE DESIGNATOR | EXTERNAL ANGLE CONNECTOR AND LUG |
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 81205 FIRST END ALL CONDUCTORS81205 FIRST END ALL CONDUCTORS |
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 81205 SECOND END ALL CONDUCTORS81205 SECOND END ALL CONDUCTORS |
TERMINAL LUG APERTURE SIZE | 0.190 INCHES SECOND END ALL CONDUCTORS0.190 INCHES SECOND END ALL CONDUCTORS |
TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | BACC45DS12C02P FIRST END ALL CONDUCTORSBACC45DS12C02P FIRST END ALL CONDUCTORS |
TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | BACT12AC8 SECOND END ALL CONDUCTORSBACT12AC8 SECOND END ALL CONDUCTORS |
TERMINATION TYPE | CONNECTOR PLUG FIRST END ALL CONDUCTORSCONNECTOR PLUG FIRST END ALL CONDUCTORS |
TERMINATION TYPE | LUG TERMINAL W/MOUNTING HOLE SECOND END ALL CONDUCTORSLUG TERMINAL W/MOUNTING HOLE SECOND END ALL CONDUCTORS |
VOLTAGE RATING | 3000.0 DIELECTRIC TEST VOLTAGE ALL CONDUCTORS3000.0 DIELECTRIC TEST VOLTAGE ALL CONDUCTORS |