5320-01-479-4271 PIN-RIVET Index 4330-01-479-4273 FILTER ELEMENT,FLUID

National Stock Number:
6515-01-479-4272

Federal Supply Class:
6515

National Item Identification Number:
014794272

Description:
RECORDER SYSTEM,DEFIBRILLATOR-MO

Detail:
A collection of items designed for use in the diagnosis and treatment of patients with cardiac arrest, arrhythmia, and those on an electrocardiograph monitor. May include monitor recorder module, defibrillator module, external paddles, external cable, cassette, electrodes, ruler, stylus, chart paper, and the like. May be mounted to field litter and field bed.


Manufacturer Information:
00-074789875DEFENSE LOGISTICS AGENCY DIRECTORATE OF MEDICAL MATERIEL DEFENSE SUPPLY CENTER PHILADELPHIA
HEARTSTREAM FR2 AED0ZBJ4PHILIPS NORTH AMERICA LLC
M3680A W/ECG0ZBJ4PHILIPS NORTH AMERICA LLC
M3860A0ZBJ4PHILIPS NORTH AMERICA LLC
M3860A OPT ABA0ZBJ4PHILIPS NORTH AMERICA LLC


Techincal Specification:
DISPOSITION AFTER INITIAL USEREUSABLE
PART NAME ASSIGNED BY CONTROLLING AGENCYDEFIBRILLATOR/MONITOR-RECORDER SYSTEM REUSABLE
MODEL NUMBERM3860A, OPT ABA
SPECIAL FEATURESHEARTSTREAM FR2 AED, INCLUDES ONE USER'S GUIDE, 2 PACK DP2 AND 6 PACK DISPOSABLE, SELF-ADHERING DEFIB PADS W/INTEGRATED CABLE AND CONNECTOR; TRAY FOR DATA CARD, AND A QUICK REFERENCE CARD, UNAMBIGIOUS VOICE COMMANDS AND CLEAR, READABLE TEXT PROMPTS; SIMPLE 1-2-3 LAYOUT GUIDES USERS TO A RAPID RESPONSE;SEMIAUTOMATIC OPERATING MODE; CHARGE TIME FROM SHOCK ADVISED; TYPICALLY LESS THAN 10 SEC; SINGLE ENERGY OUTPUT, EXTENSIVE TEXT PROMPTS AND AUDIBLE MESSAGE GUIDE USER THRU PROTOCOL; 2.6X8.5X8.5 IN., 4.7 LBS WITH 12 VDC 4.2 LIMNO2 DISPOSABLE LONG LIFE BATTERY WITH CAPACITY OF 300 SHOCKS OR 12 HR OP TIME; ELAPSED TIME AND NUMBER OF SHOCKS DELIVERED DISPLAYED ON SCREEN; AUTOMATIC SELF TESTS; AUTOMATIC STAND-BY
SUPPLEMENTARY FEATURESECG: HIGH RESOLUTION LCD SCREEN W/BRIGHT BACKLIGHT; 30 TP 300 BPM HEART RATE UPDATED EACH ANALYSIS PERIOD DURING MONITORING; 1 TO 20 HZ FREQUENCY RESPONSE; ECG SMART ANALYSIS PROVIDES EXCEPTIONAL LEVEL OF ACCURACY; GREATLY REDUCING POSSIBILITY OF INAPPROPRIATE SHOCK DELIVERY; EXCEEDS PERFORMANCE REQUIREMENTS FOR AAMI AND AHA STANDARDS FOR SPECIFICITY AND SENSITIVITY; PROMPTLY DISPAYS ECG ALONG WITH OTHER IMPORTANT INFORMATION SUCH AS HEART RATE; TOTAL SHOCKS DELIVERED; LENGTH OF TIME DEVICE IS IN USE AND ON-SCENE EVENT REVIEW; ALLOWS VIEW OF CURRENT STATUS AND A CHRONOLOGY OF EVENTS FROM THE RESCUE ATTEMPT
UNIT PACKAGE QUANTITY1