INSTALLATION DESIGN | PANEL |
INDICATOR TYPE | DIAL W/POINTER |
MEASUREMENT RANGE | 0.0 TO 50.0 MICROAMPERES, DC SINGLE INDICATOR SINGLE RANGE |
ACCURACY IN PERCENT | -3.0 TO 3.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
SCALE GRADUATION TYPE | LINEAR SINGLE INDICATOR SINGLE RANGE |
SCALE DIVISION QUANTITY | 25 SINGLE INDICATOR SINGLE RANGE |
POINTER COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
BACKGROUND COLOR | WHITE SINGLE INDICATOR SINGLE RANGE |
MOVEMENT TYPE | MOVING IRON VANE |
MOVEMENT SUSPENSION METHOD | JEWEL PIVOT BASE |
CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 SOLDER LUG OR |
| 2 SOLDER STUD |
SENSITIVITY RATING | 250.0 MILLIVOLTS |
SCALE SELECTION METHOD | TERMINAL |
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1500.0 |
POWER SOURCE | EXTERNAL |
CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
STYLE DESIGNATOR | RECTANGULAR FLUSH MTG |
METER BODY DIAMETER BEHIND MOUNTING FLANGE | 1.510 INCHES MAXIMUM |
METER DEPTH BEHIND MOUNTING FLANGE | 1.000 INCHES MAXIMUM |
OVERALL HEIGHT | 1.810 INCHES MAXIMUM |
OVERALL LENGTH | 1.625 INCHES MAXIMUM |
OVERALL WIDTH | 1.810 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 4 SCREW AND |
| 4 UNTHREADED HOLE |
MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL |
MOUNTING ARRANGEMENT STYLE | FOUR HOLE/STUD RECTANGULAR/SQUARE |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.306 INCHES MINIMUM AND |
| 1.318 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.306 INCHES MINIMUM AND |
| 1.318 INCHES MAXIMUM |
PANEL FOR WHICH DESIGNED | MAGNETIC |
CIRCUIT CONSTRUCTION TYPE | NONELECTRONIC |
MATERIAL | ALUMINUM AND |
| STEEL |
SURFACE TREATMENT | PAINT |
NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
ENVIRONMENTAL PROTECTION | COLD RESISTANT AND |
| HEAT RESISTANT AND |
| SHOCK RESISTANT AND |
| SUBMERSIBLE AND |
| VIBRATION RESISTANT AND |
| WATERTIGHT |
FURNISHED ITEMS AND QUANTITY | NUT 4 |
FEATURES PROVIDED | LUMINOUS SCALE MARKING AND |
| MAGNETIC SHIELD |
SPECIAL FEATURES | WITH OR WITHOUT ZERO ADJUSTER |
TEST DATA DOCUMENT | 81349-MIL-M-10304 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIAL TEST FEATURES | CRITICAL APPLICATION-ACFT: STRATOLIFTER C-135 AND HERCULES C-130; SPRT EQUIP.: F-4 ACFT,T-37 ACFT,F-16 ACFT AND T-38 ACFT; CHAPARRAL/VULCAN ADS; COMM TERM.,SATELLITE AN/TSC-93A; GND MOBILE FORCE SATELLITE COMM TERM. AN/TSC-93A |
SPECIFICATION/STANDARD DATA | 81349-MIL-M-10304/24 GOVERNMENT SPECIFICATION |
CRITICALITY CODE JUSTIFICATION | SPCL |
SPEC/STD CONTROLLING DATA | |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-10304/24 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MR13W050DCUAR |