1560-01-081-5700 RIB,BUMP,WING FILLET Index 5990-01-081-5702 SYNCHRO,RECEIVER

National Stock Number:
6625-01-081-5701

Federal Supply Class:
6625

National Item Identification Number:
010815701

Description:
METER,POWER FACTOR

Detail:
AN INSTRUMENT WHICH MEASURES THE RATIO BETWEEN ACTUAL POWER AND APPARENT POWER IN AN ELECTRICAL CIRCUIT AND IS USUALLY CALIBRATED IN PERCENT. THE VALUE MAY BE EXPRESSED BY MEANS OF A POINTER AND CALIBRATED DIAL OR A DIGITAL READOUT DISPLAY. EXCLUDES WATTMETER.


Manufacturer Information:
2830-1402FCAD63638SQUARE D CO PINELLAS PLANT
4951-74233005JEWELL INSTRUMENTS LLC
63030-260-5012670SQUARE D CO ELECTROMAGNETIC INDUSTRIES DIV
EA1PU-5-12012670SQUARE D CO ELECTROMAGNETIC INDUSTRIES DIV
76-1121630554DEPARTMENT OF DEFENSE PROJECT MANAGER-MOBILE ELECTRIC POWER
63030-260-5063638SQUARE D CO PINELLAS PLANT
EA1PU-5-12063638SQUARE D CO PINELLAS PLANT


Techincal Specification:
INSTALLATION DESIGNPANEL
INDICATOR TYPEDIAL W/POINTER
MEASUREMENT RANGE0.0 TO 5.0 AMPERES, AC SINGLE INDICATOR SINGLE RANGE
ACCURACY IN PERCENT-1.0 TO 1.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
SCALE GRADUATION TYPELINEAR SINGLE INDICATOR SINGLE RANGE
SCALE DIVISION QUANTITY6 SINGLE INDICATOR SINGLE RANGE
POINTER COLORBLACK SINGLE INDICATOR SINGLE RANGE
DIAL SCALE MARKING COLORBLACK SINGLE INDICATOR SINGLE RANGE
ACCURACY RATINGPORN 1 PCT READING FULL SCALE SINGLE INDICATOR SINGLE RANGE
DISPLAY COLORWHITE OR
BLACK SINGLE INDICATOR SINGLE RANGE
BACKGROUND COLORWHITE SINGLE INDICATOR SINGLE RANGE
MOVEMENT TYPEELECTROSTATIC
CIRCUIT ATTACHMENT METHOD AND QUANTITY4 WIRE LEAD
SENSITIVITY RATING5.0 AMPERES
CIRCUIT CURRENT FOR WHICH DESIGNEDAC
OPERATING VOLTAGE RATING IN VOLTS120.0 AC NOMINAL
FREQUENCY RATING50.0 HERTZ MINIMUM AND
60.0 HERTZ MAXIMUM
PHASETHREE
STYLE DESIGNATORRECTANGULAR SURFACE MTG
OVERALL HEIGHT4.310 INCHES NOMINAL
OVERALL LENGTH7.020 INCHES NOMINAL
OVERALL WIDTH4.310 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
MOUNTING HOLE DIAMETER0.250 INCHES NOMINAL
MOUNTING ARRANGEMENT STYLEFOUR HOLE/STUD RECTANGULAR/SQUARE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.375 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.375 INCHES NOMINAL
NUCLEAR HARDNESS CRITICAL FEATURENONHARDENED
SPECIAL FEATURESUSE ON GENERATOR SET,DED,CURRENT AC,400.0KW-NSN 6115-01-030-6085
SPEC/STD CONTROLLING DATA
MANUFACTURERS CODE30554
MFR SOURCE CONTROLLING REFERENCE76-11216