National Stock Number: 6635-00-296-3332
Federal Supply Class: 6635
National Item Identification Number: 002963332
Description: TEST SET,ULTRASONIC
Detail: AN ITEM FOR NON-DESTRUCTIVE TESTING USING ULTRASONIC FREQUENCIES TO TEST FOR FLAWS, CRACKS, DISBONDS AND THE LIKE IN METALLIC AND NONMETALLIC MATERIALS. THIS ITEM USES TRANSDUCER, ULTRASONIC TEST. THIS EXCLUDES DETECTOR, METAL FLAW ELECTRONIC.
|
Manufacturer Information:
6635-7552-0500 | 99998 | DEFENSE SUPPLY CENTER RICHMOND INDUSTRIAL PLANT EQUIPMENT /DLA/ | A-A-58073 | 81348 | FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC | UM775-10WRFV | 1KY21 | OLYMPUS AMERICA INC | UM775-50D765 | 1KY21 | OLYMPUS AMERICA INC | UM775-50D765 | 29192 | OLYMPUS SCIENTIFIC SOLUTIONS TECHNOLOGIES INC. | UM775-10WRFV | 29192 | OLYMPUS SCIENTIFIC SOLUTIONS TECHNOLOGIES INC. |
|
Techincal Specification:
CARRYING CASE | PROVIDED | FUNCTIONAL DESCRIPTION | USED AS THICKNESS GAGE; DETECTS,LOCATES AND EVALUATES DEFECTS SUCH AS CRACKS,DEFECTS,DETERORIATION,CORROSION FOREIGN INCLUSION IN METALLIC & NON-METALLIC MATERIALS | INDICATOR DESIGN | DIRECT READING | INDICATOR READING TYPE | SINGLE | INDICATOR TYPE | ELECTRON-RAY TUBE | INSTALLATION DESIGN | PORTABLE | SPECIAL FEATURES | 21.000 IN. L,14.000 IN.W,8.000 IN. H; 90 TO 130 VAC,50 TO 60 HZ,100 WATTS; PULSER RECEIVER PLUG IN INCLUDED | TEST TYPE | DISTORTION | USAGE DESIGN | EXTERNAL |
|
|