ELECTRICAL CONNECTION TYPE | CABLE |
AC VOLTAGE RATING | 115.0 VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
CONTACT ARRANGEMENT | SPST,NORMAL OPEN |
CRITICALITY CODE JUSTIFICATION | ZZZY |
CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 MILLIAMPERES NOMINAL LOAD |
DC VOLTAGE RATING | 115.0 VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
FLOAT EFFECTIVE TRAVEL | 0.250 INCHES MINIMUM AND 0.500 INCHES MAXIMUM |
FLOAT QUANTITY | 1 |
FREQUENCY RATING | 60.0 HERTZ NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED 1ST ALTERNATE OPERATING POWER RQMT |
LIQUID TYPE FOR WHICH DESIGNED | SEA WATER AND WATER |
OVERALL DIAMETER | 2.562 INCHES NOMINAL |
OVERALL LENGTH | 3.312 INCHES NOMINAL |
MOUNTING DIMENSIONS | MTG BY TWO 9/16 IN. DIA HOLES EQUALLY SPACE 1.750 IN. C TO C |
MOUNTING POSITION | VERTICAL |
MOUNTING METHOD | BRACKET |
OPERATING TEMP RATING | 0.0 FAHRENHEIT MINIMUM AND 150.0 FAHRENHEIT MAXIMUM |
PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
POWER CABLE LENGTH | 300.000 INCHES NOMINAL |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | MATERIAL WILL BE IN ACCORDANCE WITH SHIPS PARTS CONTROL CENTER ACTIVITY HX QUALITY CONTROL,MANUFACTURING AND TESTING SPECIFICATIONS |
RELAY | NOT INCLUDED |
SPECIAL FEATURES | FLOAT POSITION:DOWN |