ELECTRICAL CONNECTION QUANTITY | 2 |
ELECTRICAL CONNECTION IDENTIFYING NUMBER | MS33678C-18-9P AND HERMETICALLY SEALED; PIN A SHALL BE ALUMEL / PIN D SHALL BE CHROMEL |
PRESENTATION TYPE | DIAL AND |
| DIGITAL DISPLAY |
SCALE DIVISION QUANTITY | 12 1ST INDICATOR SINGLE SCALE |
| 10 2ND INDICATOR SINGLE SCALE |
SCALE MARKING AND SURFACE FINISH | NUMERALS LUMINOUS |
SCALE RANGE | 0.0 TO 12.0 TEMPERATURE 1ST INDICATOR DEGREE CELSIUS |
| 0.0 TO 9.0 TEMPERATURE 2ND INDICATOR DEGREE CELSIUS |
POINTER TYPE | INDICATING 1ST POINTER |
| INDICATING 2ND POINTER |
DISPLAY TYPE | LIQUID CRYSTAL |
DISPLAY DIGIT QUANTITY | 7 |
CURRENT TYPE | AC/DC |
AC VOLTAGE RATING | 115.0 VOLTS NOMINAL |
PHASE | SINGLE |
FREQUENCY RATING | 400.0 HERTZ NOMINAL |
CONTACT QUANTITY | 7 |
CONTACT TYPE | PIN |
SPECIAL FEATURES | SHALL CONFORM TO FAA TSO-C43C FOR TYPE II INDICATORS, MINIMUM VIEWING ANGLE SHALL BE 30 DEGREES FROM EITHER SIDE OF CENTER LINE, INDICATOR WILL PROVIDE POWER OFF WARNING AND SELF TEST FOR EACH DISPLAY SEGMENT FOR 2 SECONDS MINIMUM, WILL USE +5 VOLTS AC OR DC ON PIN E FOR LIGHTING; CASE WILL CONFOR M TO MS33639D FOR 2 INCH SIZE; INDICATOR WILL HAVE FACILITIES FOR EVACUATING AND FILLING THE CASE WITH MEDIUM TO AN ABSOLUTE PRESSURE OF 12 TO 14.7 PSI, INDICATOR WILL HAVEA SEVEN SEGMENT N UMERIC DISPLAY TO AUGMENT POINTER READING THROUGHOUT FULL SCALE RANGE, INDICATOR WILL BE NVIS COMPATIBLE |