4820-01-150-6412 VALVE,CHECK Index 5915-01-150-6416 FILTER,BAND SUPPRESSION

National Stock Number:
5915-01-150-6414

Federal Supply Class:
5915

National Item Identification Number:
011506414

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
10B6657996FILTER RESEARCH CORPORATION
MB-153508715CEN ELECTRONICS A DIV OF CHLORIDE POWER ELECTRONICS INC
SM-A-838216-654832AEROFLEX LABORATORIES INC COMSTRON DIV
SM-A-838216-657996FILTER RESEARCH CORPORATION
SM-A-838216-680063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY HEIGHT0.580 INCHES MAXIMUM
BODY LENGTH3.035 INCHES MAXIMUM
BODY SURFACE TREATMENTTIN
BODY WIDTH1.875 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM 1ST BAND PASS AND 3.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM 2ND BAND PASS AND 3.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM 3RD BAND PASS AND 3.0 MAXIMUM 3RD BAND PASS 3RD FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM 4TH BAND PASS AND 3.0 MAXIMUM 4TH BAND PASS 4TH FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM 5TH BAND PASS AND 3.0 MAXIMUM 5TH BAND PASS 5TH FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.624 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN GROUND 3RD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY5 PIN OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION20.944 KILOHERTZ 2ND BAND PASS AND 21.792 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION23.168 KILOHERTZ 3RD BAND PASS AND 24.096 KILOHERTZ 3RD BAND PASS 3RD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION35.28 KILOHERTZ 4TH BAND PASS AND 36.72 KILOHERTZ 4TH BAND PASS 4TH FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION14.752 KILOHERTZ 1ST BAND PASS AND 15.344 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION40.784 KILOHERTZ 5TH BAND PASS AND 42.416 KILOHERTZ 5TH BAND PASS 5TH FUNCTION
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST BAND PASS 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 2ND BAND PASS 2ND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 3RD BAND PASS 3RD FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 5TH BAND PASS 5TH FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 4TH BAND PASS 4TH FUNCTION
LOAD IMPEDANCE PER FUNCTION100.0 KILOHMS 2ND BAND PASS 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION100.0 KILOHMS 3RD BAND PASS 3RD FUNCTION
LOAD IMPEDANCE PER FUNCTION100.0 KILOHMS 1ST BAND PASS 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION100.0 KILOHMS 4TH BAND PASS 4TH FUNCTION
LOAD IMPEDANCE PER FUNCTION100.0 KILOHMS 5TH BAND PASS 5TH FUNCTION
OVERALL HEIGHT0.850 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY5 PLUG-IN
OPERATING TEMP RANGE-29.0 TO 85.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION15.056 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
REFERENCE FREQUENCY PER FUNCTION21.376 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
REFERENCE FREQUENCY PER FUNCTION23.632 KILOHERTZ 3RD BAND PASS 3RD FUNCTION
REFERENCE FREQUENCY PER FUNCTION36.0 KILOHERTZ 4TH BAND PASS 4TH FUNCTION
REFERENCE FREQUENCY PER FUNCTION41.6 KILOHERTZ 5TH BAND PASS 5TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 1ST BAND PASS 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 2ND BAND PASS 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 3RD BAND PASS 3RD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 4TH BAND PASS 4TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 5TH BAND PASS 5TH FUNCTION
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ6.500
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION20.736 KILOHERTZ 2ND BAND PASS AND 20.944 KILOHERTZ 2ND BAND PASS AND 21.792 KILOHERTZ 2ND BAND PASS AND 22.032 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION22.928 KILOHERTZ 3RD BAND PASS AND 23.168 KILOHERTZ 3RD BAND PASS AND 24.096 KILOHERTZ 3RD BAND PASS AND 24.352 KILOHERTZ 3RD BAND PASS 3RD FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION34.928 KILOHERTZ 4TH BAND PASS AND 35.28 KILOHERTZ 4TH BAND PASS AND 36.72 KILOHERTZ 4TH BAND PASS AND 37.072 KILOHERTZ 4TH BAND PASS 4TH FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION14.608 KILOHERTZ 1ST BAND PASS AND 14.752 KILOHERTZ 1ST BAND PASS AND 15.344 KILOHERTZ 1ST BAND PASS AND 15.52 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION40.352 KILOHERTZ 5TH BAND PASS AND 40.784 KILOHERTZ 5TH BAND PASS AND 42.416 KILOHERTZ 5TH BAND PASS AND 42.848 KILOHERTZ 5TH BAND PASS 5TH FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0


Click here to Register for Free 30-day Trial