5915-01-150-6414 FILTER,BAND PASS Index 5915-01-150-6417 FILTER,LOW PASS

National Stock Number:
5915-01-150-6416

Federal Supply Class:
5915

National Item Identification Number:
011506416

Description:
FILTER,BAND SUPPRESSION

Detail:
AN ITEM DESIGNED TO SUPPRESS FREQUENCIES WITHIN A SPECIFIED RANGE (BAND) AND TO PASS FREQUENCIES OUTSIDE THE RANGE (BAND). EXCLUDES A SINGLE INDUCTANCE, A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).


Manufacturer Information:
10R0357996FILTER RESEARCH CORPORATION
R-162108715CEN ELECTRONICS A DIV OF CHLORIDE POWER ELECTRONICS INC
SM-A-838214-154832AEROFLEX LABORATORIES INC COMSTRON DIV
SM-A-838214-157996FILTER RESEARCH CORPORATION
SM-A-838214-180063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY HEIGHT0.580 INCHES MAXIMUM
BODY LENGTH3.035 INCHES MAXIMUM
BODY WIDTH2.250 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS7.5 MAXIMUM 1ST BAND SUPPRESSION AND 25.0 MINIMUM 1ST BAND SUPPRESSION 1ST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS7.5 MAXIMUM 2ND BAND SUPPRESSION AND 25.0 MINIMUM 2ND BAND SUPPRESSION 2ND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.750 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN GROUND 3RD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION18.88 KILOHERTZ 1ST BAND SUPPRESSION AND 42.64 KILOHERTZ 1ST BAND SUPPRESSION 1ST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION10.88 KILOHERTZ 2ND BAND SUPPRESSION AND 15.44 KILOHERTZ 2ND BAND SUPPRESSION 2ND FUNCTION
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 2ND BAND SUPPRESSION 2ND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST BAND SUPPRESSION 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION1.0 KILOHMS 1ST BAND SUPPRESSION 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION1.0 KILOHMS 2ND BAND SUPPRESSION 2ND FUNCTION
OVERALL HEIGHT0.850 INCHES MAXIMUM
OPERATING TEMP RANGE-29.0 TO 85.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION13.16 KILOHERTZ 2ND BAND SUPPRESSION 2ND FUNCTION
REFERENCE FREQUENCY PER FUNCTION30.76 KILOHERTZ 1ST BAND SUPPRESSION 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 1ST BAND SUPPRESSION 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 2ND BAND SUPPRESSION 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION15.44 KILOHERTZ 1ST BAND SUPPRESSION AND 18.88 KILOHERTZ 1ST BAND SUPPRESSION AND 42.64 KILOHERTZ 1ST BAND SUPPRESSION AND 52.00 KILOHERTZ 1ST BAND SUPPRESSION 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION8.00 KILOHERTZ 2ND BAND SUPPRESSION AND 10.88 KILOHERTZ 2ND BAND SUPPRESSION AND 15.44 KILOHERTZ 2ND BAND SUPPRESSION AND 18.88 KILOHERTZ 2ND BAND SUPPRESSION 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE