5970-01-053-5136 INSULATION SLEEVING,ELECTRICAL Index 5970-01-053-5138 INSULATION SLEEVING,ELECTRICAL,S

National Stock Number:
5970-01-053-5137

Federal Supply Class:
5970

National Item Identification Number:
010535137

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
502A834-306090TE CONNECTIVITY CORPORATION


Techincal Specification:
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER0.280 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.800 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYSEMIRIGID
FOURTH BRANCH INSIDE DIAMETER0.280 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FOURTH BRANCH INSIDE DIAMETER0.800 INCHES MINIMUM AS SUPPLIED
FOURTH BRANCH WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH4.250 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.090 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER2.050 INCHES MINIMUM AS SUPPLIED
MATERIAL DOCUMENT AND CLASSIFICATIONRT-301, RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED
MATERIALPLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
SECOND BRANCH INSIDE DIAMETER0.280 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.800 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
TEMP RATING-55.0 CELSIUS
THIRD BRANCH INSIDE DIAMETER0.280 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.800 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY